In preparation for fire break-outs, walk-on floors and stairs require fireresistant glass that can bear load. Glass intended for such use is tested and certified for load-bearing.
After measuring the fire-resistance index (E) and the insulation index (I), the glass is indexed for load bearing capacity in fire incidents (R).
POLFLAM offers POLFLAM® F glass for glazed ceilings of fire-resistance classes REI 30, REI 45 and REI 60 and the load-bearing capacity of as high as 5 kN/ sq m.
The glass’ thickness is in the range of 46 to 62 mm, depending on its dimensions. Fire-resistant glazed ceilings and stairs allow light saturation inside as difficult spaces as staircases. They are therefore the solution sought by architects.
Using POLFLAM® F glass panels, one can also form a variety of geometric shapes, inside rectangular perimeters, of maximum dimensions 2200 x 1650 mm.
POLFLAM® F glass is also completely safe for ordinary day-to-day applications as it can be coated with antiskid screen print.
POLFLAM® F glass complies with the load-bearing, insulation, and fire-resistance criteria, in accordance with PN-EN 1365-2:2014 standards. It has successfully passed tests carried out by a notified European body.